Sign In | Join Free | My himfr.com
Home > Electric Testing Equipment >

Three Phase Power Quality Analyzer, Power Quality Data Logger

Delta Technology (Chongqing) Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Three Phase Power Quality Analyzer, Power Quality Data Logger from wholesalers
     
    Buy cheap Three Phase Power Quality Analyzer, Power Quality Data Logger from wholesalers
    • Buy cheap Three Phase Power Quality Analyzer, Power Quality Data Logger from wholesalers
    • Buy cheap Three Phase Power Quality Analyzer, Power Quality Data Logger from wholesalers
    • Buy cheap Three Phase Power Quality Analyzer, Power Quality Data Logger from wholesalers
    • Buy cheap Three Phase Power Quality Analyzer, Power Quality Data Logger from wholesalers
    • Buy cheap Three Phase Power Quality Analyzer, Power Quality Data Logger from wholesalers
    • Buy cheap Three Phase Power Quality Analyzer, Power Quality Data Logger from wholesalers

    Three Phase Power Quality Analyzer, Power Quality Data Logger

    Ask Lasest Price
    Brand Name : Delta
    Model Number : ETCR-5000
    Certification : ISO9001
    Price : USD1.0 / set Power Quality Data Logger
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 100 sets Power Quality Data Logger / month
    Delivery Time : Within 10 days after the order is confirmed
    • Product Details
    • Company Profile

    Three Phase Power Quality Analyzer, Power Quality Data Logger

    Three Phase Power Quality Analyzer, Power Quality Data Logger

    Introduction:
    ETCR-5000 Three Phase Power Quality Analyzer, Power Quality Data Logger is specially designed for comprehensive analysis and diagnosis on all the voltage, current, power, power, harmonic, and phase electric parameters.

    It applies to the electricity industry, petrochemical, metallurgy, railway, mining enterprises, scientific research institutions, and metrological department.
    ETCR-5000 3 Phase Power Quality Analyzer Power Quality Data Logger is suitable for field tests of three phases, multi-functional and intelligent, concise man-machine operation.

    Parameters:

    Influence factorTest itemBase conditionWorking condition
    Environment temperatureAll parameters(23±2)°C-10°C~ 40°C
    Relative humidityAll parameters40%~ 60%<80%
    Phase-to-neutral voltageAll parameters(100±1%)V1.0V~ 1000V
    Phase-to-phase voltageTrue RMS phase-to-phase voltage(200±1%)V1.0V~ 2000V
    CurrentTrue RMS current(5±1%)A10mA~ 1000A
    Network frequencyAll parameters50Hz±0.1Hz40Hz~ 70Hz
    Phase shiftActive power and active energyCosφ=1Cosφ: 0.2~ 1.0
    Reactive power and reactive energySinφ=1Sinφ: 0.2~ 1.0
    HarmonicAll parameters<0.1%0.0%~ 100%
    Voltage unbalanceAll parameters<10%0.0%~ 100%
    Working voltage of deviceAll parametersDC9.8V±0.1VDC9.5V~ 10.5V
    External electric field,
    magnetic field
    All parametersShould be avoided
    Test positionMeasured related parameters of currentTested wire at the center of clamp.
    Three Phase Power Quality Analyzer, Power Quality Data LoggerThree Phase Power Quality Analyzer, Power Quality Data LoggerThree Phase Power Quality Analyzer, Power Quality Data LoggerThree Phase Power Quality Analyzer, Power Quality Data Logger
    Power supplyRechargeable lithium-ion battery pack 9.6V, backup charger.
    Battery indicatorBattery symbol shows dump energy. When the voltage is too low, automatic shutdown after 1 minute.
    Power consumptionCurrent consumption of normal test 490 mA, continuous working for 8 hours.
    Display modeLCD color screen, 640dots*480dots, 5.6 inches, display domain: 116mm*88mm.
    Size of clamp008 small sharp current clamp: 7.5mm*13mm;
    040 circle current clamp: 35mm*40mm;
    068 circle current clamp: 68mm*68mm;
    Instrument dimensionsL*W*H: 240mm*170mm*68 mm.
    Number of channels4U/4I.
    Phase-to phase voltage1.0V~2000V.
    Phase-to-neutral voltage1.0V~1000V.
    Current008 current clamp: 10mA~10.0A;
    040 current clamp: 0.10A~100A;
    068 current clamp: 1.0A~1000A;
    Optional current transformer: instrument input current 1mA~500mA.
    Frequency40Hz~70Hz.
    Parameters of electricityW, VA, Var, PF, DPF, cosφ, tanφ.
    Energy parametersWh, Varh, Vah.
    HarmonicOrder 0~50.
    Total harmonic distortionOrder 0~50, each phase.
    Expert modeYes.
    Number of Transient records150 sets.
    Voltage flickerYes.
    Starting current modeYes, 100 seconds.
    3 phases unbalanceYes.
    Record300 days(simultaneous recording 20 parameters, record one point every 5 seconds).
    Min/Max recorded valueMeasurement of maximum and minimum values over a period of time.
    Alarm40 different types of parameter selections, 12,800 sets alarm logs.
    PeakYes.
    Phasor diagram displayAutomatically.
    Capacity of snapshots60.
    Menu languageEnglish/Chinese.
    CommunicationUSB.
    Automatic switching offWhen an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress, the device is not automatic switching off.
    In other test mode, 15 minutes without keystrokes, automatic shutdown after prompt 1 minute.
    Backlight functionYes, suitable for use at night and dark place.
    WeightHost: 1.6kg (with battery).
    008 small sharp current clamp: 170g*4;
    040 circle current clamp: 190g*4;
    068 circle current clamp: 510g*4;
    Test wires and power adapter: 900g;
    Total weight: about 10.5kg (with packaging).
    Length of voltage test wire3m.
    Length of current sensor wire2m.
    Working temperature and humidity-10°C~40°C; below 80%Rh.
    Storage environment-10°C~60°C; below 70%Rh.
    Input impedanceInput impedance of test voltage: 1MΩ.
    Withstand voltageWithstand 3700V/50Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell.
    InsulationBetween instrument wiring and shell ≥10MΩ.
    StructureDouble insulation, with insulation vibration-proof sheath.
    Safely rulesIEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2.
    Packing Size400*270*270(mm) (L*W*H)
    Weight8Kg
    Three Phase Power Quality Analyzer, Power Quality Data LoggerThree Phase Power Quality Analyzer, Power Quality Data LoggerThree Phase Power Quality Analyzer, Power Quality Data LoggerThree Phase Power Quality Analyzer, Power Quality Data Logger

    Functions:
    Waveform real-time display (4 channels voltage/4 channels current).
    True RMS values of voltages and currents.
    The DC components of voltages.
    Peak current and voltage values.
    Minimum and maximum half-cycle RMS current and voltage values.
    Phasor diagram display.
    Measurement of each harmonic up to order 50.
    Bar charts show harmonic ratios of current and voltage of each phase.
    Total harmonic distortion (THD).
    Active, reactive, apparent power, by phase and cumulative.
    Active, reactive, apparent energy, by phase and cumulative.
    Transformer K factor.
    Power factors (PF) and displacement factors (DPF or COSΦ).
    Short-term voltage flicker (PST).
    Three phase unbalance(current and voltage).


    Three Phase Power Quality Analyzer, Power Quality Data LoggerThree Phase Power Quality Analyzer, Power Quality Data Logger

    Quality Three Phase Power Quality Analyzer, Power Quality Data Logger for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Delta Technology (Chongqing) Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)