Sign In | Join Free | My himfr.com
Home > Transformer Testing Equipment >

CPT-III Current Transformer and Voltage Potential Transformer Testing Equipment

Delta Technology (Chongqing) Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap CPT-III Current Transformer and Voltage Potential Transformer Testing Equipment from wholesalers
     
    Buy cheap CPT-III Current Transformer and Voltage Potential Transformer Testing Equipment from wholesalers
    • Buy cheap CPT-III Current Transformer and Voltage Potential Transformer Testing Equipment from wholesalers
    • Buy cheap CPT-III Current Transformer and Voltage Potential Transformer Testing Equipment from wholesalers
    • Buy cheap CPT-III Current Transformer and Voltage Potential Transformer Testing Equipment from wholesalers
    • Buy cheap CPT-III Current Transformer and Voltage Potential Transformer Testing Equipment from wholesalers
    • Buy cheap CPT-III Current Transformer and Voltage Potential Transformer Testing Equipment from wholesalers

    CPT-III Current Transformer and Voltage Potential Transformer Testing Equipment

    Ask Lasest Price
    Brand Name : Delta
    Model Number : CPT-III
    Certification : ISO9001
    Price : USD1.0
    Payment Terms : T/T, Western Union
    Supply Ability : 1000 sets per month
    Delivery Time : 10-20 days
    • Product Details
    • Company Profile

    CPT-III Current Transformer and Voltage Potential Transformer Testing Equipment

    CPT-III Current Transformer and Voltage Potential Transformer Testing Equipment

    Introduction:

    CPT-III Current Transformer and Voltage Potential Transformer Testing Equipment is used to measure all kinds of current transformer and voltage transformer.

    CPT-III Current Transformer and Voltage Potential Transformer Testing Equipment can calculate the ratio errors and phase angle errors of current transformer and voltage transformer at rated burden and working burden in one test.

    CPT-III Current Transformer and Voltage Potential Transformer Testing Equipmentcan automatically evaluate the test results according to the selected standard to determine whether the transformer is qualified.

    Application:

    Tests for current transformer:

    1. Excitation curve and parameters test
    2. Turns ratio test
    3. Ratio and phase error test
    4. Polarity mark check
    5. Winding resistance measurement
    6. Secondary loop burden measurement
    7. Error line curve test for protection CT
    8. Transient CT parameters test
    9. CT nameplate guess
    10. Saturation hysteresis loop curve measurement

    Tests for voltage transformer:

    1. Turns ratio test
    2. Ratio error and phase angle error test
    3. Polarity test
    4. Secondary burden test
    5. Winding resistance test

    Applications for CTPT analyzer:

    • CT nameplate check
    • CT parameters check in work burden
    • CT transient parameters analysis
    • CT ratio and phase error calibration
    • PT routine test


    Parameters:

    1Test standardsIEC60044-1, IEC60044-6, GB1208, GB16847, C57.13
    2Power supplyAC220V±10%,50Hz/60Hz±10%
    3Power output0.1~180V (AC)
    4Current output0.001~5A(RMS)
    5Power output300VA
    6Max. knee voltage measurement45kv
    7Current measurement range0~10A (automatically change range in 0.1/0.4/2/10A)
    8Current measurement error<±0.1%+0.01%FS
    9Voltage measurement range0~200 V (automatically change range in 1V/10V/70V/200V)
    10Voltage measurement error< ±0.1%+0.01%FS
    11Turns ratio measurement range

    1~35000;

    1~2000 error<0.05%;

    2000~5000 error>0.1%;

    5000~35000 error<0.2%

    12Phase measurementerror:±2min,resolution:0.01min
    13Coil resistance measurement

    Range: 0~8kΩ(automatically change range in 2ohm /20ohm /80ohm/800ohm/8kohm)

    Error< 0.2%RDG+0.02%FS

    Maximum resolution: 0.1mΩ

    14Temperature measurement-50~100 Celsius degree, error<3 Celsius degree
    15CT Secondary burden

    Range 0-160ohm (automatically change range in 2ohm/ 20ohm/80ohm/160ohm)

    Error <0.2%RDG+0.02%FS

    Maximum resolution 0.001ohm

    16PT Secondary burden

    Range 0-80kohm (automatically change range in 800ohm / 8kohm /80kohm)

    Error <0.2%RDG+0.02%FS

    Maximum resolution: 0.1ohm

    17PT ratio measurement

    Range: 1~35000,

    1~5000 error<0.2%

    5000~35000 error<0.5%

    18Saved data groups>1000groups
    19Work conditionTemperature:-10℃-50℃, moist:≤90%
    20Size485mm×356mm×183mm
    21Weight<15Kg

    CPT-III Current Transformer and Voltage Potential Transformer Testing Equipment Real Picture:

    CPT-III Current Transformer and Voltage Potential Transformer Testing EquipmentCPT-III Current Transformer and Voltage Potential Transformer Testing Equipment


    Quality CPT-III Current Transformer and Voltage Potential Transformer Testing Equipment for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Delta Technology (Chongqing) Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)